245 research outputs found

    Treatment response in relation to inflammatory and axonal surrogate marker in multiple sclerosis

    Get PDF
    BACKGROUND: This study aimed to investigate if treatment response could retrospectively be related to inflammatory or axonal pathology as measured by plasma surrogate markers. METHODS: In this 1-year observational study 30 multiple sclerosis (MS) patients with relapsing-remitting disease were treated with intramuscular IFNbeta-1a or subcutaneous IFNbeta-1b. Responders and nonresponders were defined according to clinical and magnetic resonance imaging criteria. The control group consisted of 14 healthy subjects. Plasma levels of surrogate markers for inflammation (nitric oxide metabolites (NOx)), astrocytic activation (S100B) and axonal damage (NfH(SM135)) were measured using standard assays. RESULTS: There were 11 nonresponders and 19 responders to IFNbeta treatment. Median S100B levels were elevated in a higher proportion of treatment responders (63%, 42.9 pg/mL) compared to nonresponders (18%, 11.7 pg/mL, P < 0.05, Fisher's exact test) and controls (0%, 2 pg/mL, P < 0.001). Levels of NOx were found to be more frequently elevated in nonresponders (72%, 39 microM) compared to healthy controls (0%, 37 microM, P < 0.05). Levels of NfH(SM135) were more frequently elevated in responders (58%, 300 pg/mL, P < 0.001) and nonresponders (72%, 500 pg/mL, P < 0.001) compared to controls (0%, 4.5 pg/mL). CONCLUSION: Patients with relapsing-remitting MS who had surrogate marker supported evidence for astrocytic activation responded more frequently to treatment with IFNbeta

    Bilateral acute macular neuroretinopathy in a young patient: Imaging and visual field during two-year-follow-up

    Get PDF
    Acute macular neuroretinopathy (AMN) is a rare disorder. We report a case of bilateralAMN in a young female patient, without any risk factors. She referred a positive scotoma in both eyes after flu-like symptoms. Fundus examination revealed parafoveal dark-reddish oval lesions in both eyes. Therefore, we performed visual field, optical coherence tomography (OCT), fluorescein angiography (FA) and indocyanine green angiography (ICG) at baseline and several times during the two years of follow-up. The infrared (IR) imaging showed one rounded hyporeflective lesion in the left eye and two similar lesions in the right eye. The OCT demonstrated the characteristic alterations in the outer retina. The visual field also demonstrated scotomas corresponding with these lesions. The OCT and IR features disappeared at the end of the follow-up except for the left eye, which continued to have hyperreflective spots in the outer plexiform layer. The patient complained about a residual scotoma only in the left eye after two years. Our case shows a difference in disease progression in the two eyes of the same patient, suggesting that several mechanisms can be implicated in the pathology of AMN

    Artificial intelligence applications and cataract management: A systematic review

    Get PDF
    Artificial intelligence (AI)-based applications exhibit the potential to improve the quality and efficiency of patient care in different fields, including cataract management. A systematic review of the different applications of AI-based software on all aspects of a cataract patient's management, from diagnosis to follow-up, was carried out in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. All selected articles were analyzed to assess the level of evidence according to the Oxford Centre for Evidence-Based Medicine 2011 guidelines, and the quality of evidence according to the Grading of Recommendations Assessment, Development and Evaluation system. Of the articles analyzed, 49 met the inclusion criteria. No data synthesis was possible for the heterogeneity of available data and the design of the available studies. The AI-driven diagnosis seemed to be comparable and, in selected cases, to even exceed the accuracy of experienced clinicians in classifying disease, supporting the operating room scheduling, and intraoperative and postoperative management of complications. Considering the heterogeneity of data analyzed, however, further randomized controlled trials to assess the efficacy and safety of AI application in the management of cataract should be highly warranted

    Early impact of covid-19 outbreak on the availability of cornea donors: Warnings and recommendations

    Get PDF
    Keratoplasty is one of the irreplaceable treatment options for corneal diseases. Currently, there is no evidence to substantiate that harvested corneal grafts from COVID-19 patients can contain SARS-CoV-2 virus and lead to a systemic infection. Although the risk of transmission through corneal stromal tissue is low, it potentially exists. Lack of clinical data, unclear potential of donor-derived infection and non-established recommendations for transplantation during the COVID-19 pandemic have resulted in a dramatic reduction in the number of keratoplasty and cornea donors at ophthalmology departments and eye banks. To eliminate the risk of infection of recipients and medical personnel, we suggest that the blood samples of all donors should be screened with RT-PCR tests and nasopharyngeal swabs should be taken. In addition, a chest CT scan should be performed if the circulation is maintained. Moreover, the donors’ clinical and epidemiological medical history must be screened for typical symptoms and potential contact with SARS-CoV-2 carriers to reduce the risk of transmission. The Guidelines of the Eye Bank Association of America (EBAA), Global Alliance of Eye Bank Associations (GAEBA) and European Association of Tissue Banks provide useful recommendations to eliminate the risk of transmission according to previous experiences based on similar viruses

    Ultrasound Biomicroscopy Measurements of the Normal Thickness for the Ciliary Body and the Iris in a Middle East Population

    Get PDF
    Purpose: Ciliary body (CB) and iris thicknesses may change with certain eye diseases as well as between different populations. Here, we report Ultrasound Biomicroscopy Measurements (UBM) of the normal thickness for the CB and the iris from a homogenous population in the Middle East. Patients and Methods: Sonomed 35-MHz (SONOMED, INC. New York, USA) images were obtained at 4 radial meridians, and the thickness was measured at 3 locations along the radial length of the iris and at the thickest part of the CB. Parameters included mean thickness, median thickness, range, and standard deviation. Results: Of 46 adult patients, 83 normal eyes were included in this analysis. The overall mean, median iris thicknesses at the iris root, midway along the radial length of the iris, and at the juxtapupillary margin in mm were 0.42, 0.41 ± 0.08, 0.52, 0.51± 0.08, and 0.72, 0.71± 0.1, respectively. The overall mean, median thicknesses of the CB and CB + ciliary processes in mm were 0.72, 0.71 ± 0.1, and 1.42, 1.37 ± 0.2 respectively. Gender, age, side, and height had no impact on iris and/or CB thickness (p&gt;0.05). However, the iris thickness was significantly thicker in the superior quadrant than inferiorly, and in the nasal quadrant than the temporal quadrant (p=0.04), and the CB thickness and the CB + ciliary processes thickness were significantly thicker in the superior quadrant than inferiorly (P = 0.04 and 0.02 consecutively). Conclusion: We measured in this study the normal thickness of the CB and the iris in normal eyes from homogenous population in the Middle East using ultrasound biomicroscopy. Our findings are essential for the ophthalmic community worldwide and in the Middle East region and can be used as a normative thickness data for the iris and CB in healthy eyes

    Intraoperative Anterior Segment Optical Coherence Tomography in the Management of Cataract Surgery: State of the Art

    Get PDF
    Background: The introduction of non-invasive diagnostic tools in ophthalmology has significantly reshaped current clinical practice in different settings. Recently, different anterior segment (AS) intraoperative optical coherence tomography (i-OCT) systems have been employed for different interventional procedures including cataract surgery. Materials and Methods: A review on the use of AS i-OCT in the management of cataract surgery, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines (PRISMA). The level of evidence according to the Oxford Centre for Evidence-Based Medicine (OCEM) 2011 guidelines, and the quality of evidence according to the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system were assessed for all included articles. Results: Out of 6302 articles initially extracted, 6302 abstracts were identified for screening and 32 of these met the inclusion/exclusion criteria for full-text review; 19 articles were excluded. Conclusions: The use of AS i-OCT in cataract surgery, even if only a few studies have a high level or grade of evidence, may represent a useful tool for novel surgeons approaching phacoemulsification but also for expert ones for teaching purposes and to plan and manage complicated cases

    The Prognostic Value of Brain Extracellular Fluid Nitric Oxide Metabolites After Traumatic Brain Injury.

    Get PDF
    BACKGROUND: Nitric oxide (NO) is a compound with both protective and damaging effects on neurons. Quantification of NO metabolites in humans is limited by sample contamination with blood. In vivo cerebral microdialysis may offer an alternative approach as sampling of extracellular fluid (ECF) adjacent to neurons becomes possible. We investigate the prognostic value of brain ECF NO metabolites in patients with traumatic brain injury (TBI). METHODS: A prospective case cohort of 195 ECF samples collected from 11 cases over 4 days following TBI was collected. Nitrate and nitrite concentrations ([NO( x )]) were quantified using a vanadium-based colorimetric assay. RESULTS: Early ECF [NO( x )] (<48 h post TBI) were significantly higher in non-survivors (median 59.2 μmol/l, n = 7) compared to survivors (23.3 μmol/l, n = 4) (P = 0.04). Late (48-96 h) ECF [NO( x )] remained higher in non-survivors (47.9 μmol/l) compared to survivors (23.0 μmol/l) but this was not significant (P = 0.29). Receiver operator characteristic analysis shows an optimized cutoff level for ECF [NO( x )] of 26.5 μmol/l measured <48 h post TBI for predicting non-survival (sensitivity 100%, specificity 75%). CONCLUSION: Early ECF NO( x ) concentrations are of prognostic value after TBI. ECF NO( x ) may be a useful biomarker for treatment trials targeted at nitric oxide metabolism

    Bilateral Circumscribed Posterior Keratoconus: Visualization by Ultrasound Biomicroscopy and Slit-Scanning Topography Analysis

    Get PDF
    This paper documents a rare nonprogressive developmental disorder—bilateral circumscribed posterior keratoconus—in a 60-year-old man referred for a cataract surgery. For the first time ultrasound biomicroscopy was used to visualise the local anterior bulging of the posterior corneal surface with concomitant thinning of the stroma. The amount of localized posterior depression, corneal thickness and the refractive power of both the posterior and anterior corneal curvature were measured using slit-scanning topography analysis (Orbscan)
    corecore